RETURN TO
TABLE OF
CONTENTS
TROUBLESHOOTING GUIDE
ISSUE POTENTIAL CAUSE PROPOSED SOLUTION MANUAL SECTION
INSUFFICIENT WATER TO
SCRUB HEAD
SOLUTION FLOW SETTING IS TOO LOW ADJUST SOLUTION CONTROL SOLUTION DISTRIBUTION
SOLUTION TANK IS EMPTY ADD WATER/SOLUTION TO THE TANK SOLUTION DISTRIBUTION
IN-LINE SOLUTION FILTER IS CLOGGED REMOVE AND CLEAN THE FILTER SOLUTION DISTRIBUTION
SOLUTION TUBE IS CLOGGED, KINKED, OR DAMAGED INSPECT TUBES PARTS DIAGRAMS
SOLUTION SHUT OFF VALVE IS CLOSED OPEN VALVE SOLUTION DISTRIBUTION
SOLUTION SOLENOID VALVE MAY BE FAULTY VERIFY OPERATION AND REPLACE IF NECESSARY PARTS DIAGRAMS
POOR WATER RECOVERY
RECOVERY TANK IS FULL EMPTY RECOVERY TANK RECOVERY SYSTEM
DIRTY OR WORN SQUEEGEE BLADES INSPECT AND ROTATE OR REPLACE AS REQUIRED RECOVERY SYSTEM
RECOVERY HOSE LOOSE OR DAMAGED INSPECT AND REPAIR PARTS DIAGRAMS
RECOVERY HOSE OR SQUEEGEE ASSEMBLY HAS AN
OBSTRUCTION
CLEAR OBSTRUCTIONS FROM RECOVERY SYSTEM PARTS DIAGRAMS
SQUEEGEE ASSEMBLY MAY BE OUT OF ADJUSTMENT ADJUST AS NECESSARY RECOVERY SYSTEM
STUCK OR DAMAGED BALL FLOAT INSPECT AND REPAIR/REPLACE RECOVERY SYSTEM
RECOVERY TANK LID IS NOT SEALING PROPERLY INSPECT RECOVERY LID GASKET. REPAIR OR REPLACE IF NEEDED PARTS DIAGRAM
DRAIN HOSE CAP IS NOT INSTALLED PROPERLY INSTALL DRAIN HOSE SECURELY RECOVERY SYSTEM
LOW BATTERY VOLTAGE CHARGE BATTERIES CHARGING
MACHINE WILL NOT
TURN ON
FAULTY KEY SWITCH DIAGNOSE AND REPLACE WIRING DIAGRAMS
DISCHARGED BATTERIES CHARGE BATTERIES CHARGING
LOOSE OR DAMAGED WIRE REPAIR WIRING DIAGRAMS
MACHINE NOT
CLEANING FLOOR
PROPERLY
WORN PAD OR BRUSH INSPECT AND REPLACE AS REQUIRED SCRUB DECK SETUP
WRONG PAD OR BRUSH FOR APPLICATION CONTACT YOUR LOCAL DISTRIBUTOR FOR RECOMMENDED APPLICATION SCRUB DECK SETUP
INSUFFICIENT CLEANING SOLUTION FOR APPLICATION ADJUST THE MIXTURE AS REQUIRED SOLUTION DISTRIBUTION
EXCESSIVE FOAM IN
RECOVERY TANK
IMPROPER DETERGENT TYPE
USE A LOW-FOAM DETERGENT OR ADD A DEFOAMING AGENT TO THE
RECOVERY TANK. READ ALL CHEMICAL LABELS THOROUGHLY BEFORE USE
RECOVERY SYSTEM
VACUUM MOTOR WILL
NOT RUN
SQUEEGEE LIFT LEVER IS STILL RAISED LOWER SQUEEGEE LEVER RECOVERY SYSTEM
VACUUM RELAY MAY BE FAULTY CONTACT SERVICE TECHNICIAN TO TROUBLESHOOT AND ISOLATE WIRING DIAGRAMS
VACUUM SWITCH OR WIRING MAY BE FAULTY CONTACT SERVICE TECHNICIAN TO TROUBLESHOOT AND ISOLATE WIRING DIAGRAMS
VACUUM MOTOR WILL
NOT TURN OFF
STILL IN DELAY MODE ALLOW 10 SECONDS FOR VACUUM TO SHUT DOWN RECOVERY SYSTEM
VACUUM RELAY MAY BE FAULTY CONTACT SERVICE TECHNICIAN TO TROUBLESHOOT AND ISOLATE WIRING DIAGRAM