satisfactorily.
W
arning: Operating the pump dry will damage the pump seal. If the pump
has been operated dry, stop the engine immediately, and allow the pump to
cool before priming.
T
YPE OF WATER
Pumps are capable of pumping septic tank effluent, sink wastes, small
amounts of dirt or sand, drainage or polluted water and some industrial wastes.
They are not designed to pump large quantities of foreign matter. If fluid
contains large or stringy material, then an adequate suction strainer should be
used.
If chemicals are to be pumped, compatibility of pump material should be
checked with your local office.
STAETING THE ENGINE
Prime the pump
1. Move the fuel valve
level to the on position
2. Move the choke to CLOSED position. No need for restart a warm
engine
4. Move the throttle level away from SLOW position, about 1/3 of the way
toward the FAST position
5. Turn the ignition switch to ON position