S
UCTION HOSE INSTALLATION
Use the commercially available hose and hose connector with the hose clamp
provided with the pump.
Use a hose clamp to securely fasten the connector to suction hose in order to
prevent the air leakage and loss of the suction. Verify that the hose connector
sealing washer is in good condition.
Install the strainer on the other end of the suction hose, and secure it with a
clamp. The strainer will help to prevent the pump from becoming clogged or
damaged by the debris.
DISCHARGE HOSE INSTALLATION
Use a commercially available hose
And hose connector, and clamp.
It is best to use a short, large-diameter
hose. That will reduce fluid friction and
improve output.
Tighten the hose clamp securely to
Prevent the discharge hose from
disconnecting under high pressure.
PRIMING THE PUMP
Remove priming plug and fill pump and suction pipe with water. Pump is
equipped with suction flap valve and should be capable of drawing air out of
normal size suction pipes or hoses. Replace plug and start the pump. If the
pump pumps a little and stops, turn the pump off, check suction pipe for
possible leaks and repeat priming procedure until the pump operates