OM 386 pag 8 Cap 3
Where possible, it is recommended to branch always the platform to an electric
source, in fact, el.motors can be used alternatively to diesel engine, for small aerial
movements and, eventually, for recovery in emergency (i.e. diesel breakdown)
Starting procedure:
on main control desk (Fig. 3.2) rotate the key (item 8) on pos. 1 (oil and el.
tension warning lights)
branch the electric plug (fig. 3.4) and socket (16A)
verify that one of the "STOP" push-buttons is not pressed
now, acting on one control lever, electric motor run
it is also possible to stop electric motor, by acting on the same STOP push-
button of the diesel engine, or by rotating key on OFF position
electric motor re-starts, when the push-button is re-set by rotation and you
act on one control lever
Fig. 3.4
NOTE:
For the efficient functionning of magnetothermic differentials switch (life-savers)
on the machine, the electricity plug mus be safely connected to the ground and be
on a normal box; do not use flying cables sometimes existing on the working sites.
During the machine displacement on the ground, keep the max attention to not
crush the feeding cable with wheels or tracks and to the cable limit lenght.