OM 386 pag 37 Cap 3
the Palazzani Industrie S.p.A.
In the area D it’s possible to view the diagnostic messages; following a short
description:
Potentiometer 1a breakdown: it is displayed when the potentiometer exceede
the min or max setted value. During booms working, it stops also
movements which are controlled by the moment limitator. During transfer
the movement is not stopped and only the message is displayed
Potentiometer 2a breakdown: idem
Potentiometer 3a breakdown: idem
Potentiometer 4a breakdown: idem
Potentiometer 1b breakdown: idem
Potentiometer 2b breakdown: idem
Potentiometer 3b breakdown: idem
Potentiometer 4b breakdown: idem
Selfpropelling interlock: it is displayed when the stabilizers are not layed on
the ground and key selector is switched on “transfer” (and no allarm
messages are displayed)
Stabilizer interlock: it is displayed when at least one stabilizer touches the
ground and the key selector is switched on transfer (the transfer is blocked)
Uncorrect levelling of 2°: it is displayed if the machine is wrongly placed
and it doesn’t allow the booms movements. If the machine goes to an
uncorrect levelling during working, only the message is displayed.
Stabilizer pin not engaged: it is displayed during the positioning if a pin is
not inserted. It blocks the stabilizers movement
Articulation pin not engaged of 120°: it is displayed after the machine
positioning if all stabilizers in working position are not open and it doesn’t
allow the booms movement
Area manager temporarily blocking: it is displayed it is displayed during the
normal blocking of the limitator (it turns on when the machine returns in the
allowed area). The message remains displayed if an area transfer end of
stroke is defeated
Area manager permanently blocking: it is displayed if a limitator relay is
blocked or if a potentiometer has not the alligned values (the locking
limitator remains in fuction)
Wide area: it is displayed after having placed teh stabilizers correctly and
switched the key selector on boom position
Medium area: it is displayed after wide area (and there are no allarm
messages)
Narrow area: it is displayed after medium area (and there are no allarm
messages)