5 ALARM MANAGEMENT
The stove is supplied with an automatic status control
system. When a system anomaly is detected, an error
PHVVDJHLVGLVSOD\HGRQWKHFRQWUROSDQHOVFUHHQ¿J
List of alarms and possible causes:
CODE
ERROR/WARNING
DESCRIPTION POSSIBLE CAUSES
E004
NO CONNECTION
Communication error
7KHZLUHOLQNLQJWKHPRWKHUERDUGDQGWKHFRQWUROSDQHO
has been interrupted or disconnected
E101
NO IGNITION
Start-up failure
Hopper is empty
Pellet quality
,JQLWLRQV\VWHPGDPDJHG
Dirty brazier
E102
EXHAS.TEMP.
Temperature of fumes is too low
3RVVLEOHLJQLWLRQIDLOXUH
Check the pellet level in the hopper and that brazier is
clean and in the correct position.
Check that the door and the ash box are properly closed.
E103
EXHAUST FAN
)OXHJDVIDQHUURU )OXHJDVIDQLVGLVFRQQHFWHGRUIDXOW\
E104
BLACK OUT
Black-out 3RZHUIDLOXUHZKHQWKHVWRYHLVRSHUDWLQJ
E105
PELLET PROBE
Pellet probe alarm Pellet probe is disconnected or faulty
E108
THERMAL
Safety error 2YHUKHDWLQJLQWKHKRSSHU
E109
DEPRESS
Pressure error
'LUW\ÀXH
%XUQSRWJDVNHWVZRUQ
Inadequate combustion air intake
E110
ROOM PROBE
Temperature probe malfunction Faulty air probe
E111
SMOKE PROBE
Exhaust probe malfunction Faulty exhaust temperature probe
E112
PELLET TEMP
3HOOHWRYHUKHDWLQJ Possible ventilator fault
Alarm reset:
$IWHU\RXKDYHFKHFNHGWKHPHVVDJHW\SHDQGUHVROYHGWKH
SUREOHP\RXFDQUHVHW WKHZDUQLQJE\KROGLQJGRZQ WKH
ON button for a little while.
In the event of error code
E108, reactivate the manual
thermostat located at the back of the unit before resetting
WKHDODUP¿J7HFKQLFDO$VVLVWDQFH&HQWUH
At this point you can restart the stove.