48/136 cod. 004772531 - 07/2013 - Palazzetti - PN - Italy
USE AND & MAINTENANCE
9 STOVE OPERATION
9.1 STARTING THE STOVE
To start the stove hold the
button for several seconds.
Automatic stove ignition: the stove comes with an automatic device that starts the pellet stove without using other
or drying of certain materials used. This phenomenon will gradually disappear.
9.2 MODIFYING THE PARAMETERS
power supply.
9.3 SWITCHING OFF
To switch the stove off hold the
To start the stove again it’s recommended to wait for the stove to cool down completely.
The stove should only be switched off following the procedure described above. Never switch the stove off by
unplugging it from the power supply.
9.4 OPERATION WITH ROOM THERMOSTAT
When the stove is controlled by an external thermostat (or timer thermostat), the installer must have set
output (that is, the stove attempts to maintain the desired temperature while minimising fuel consumption) when
reaching the set water temperature.
The stove switches on again automatically when the temperature falls below the value set on the external
thermostat (circuit closed).
button), the stove needs to be started
The stove will go off automatically even in the case the water temperature keeps growing notwithstanding the modulation
mode. In this case the stove will ignite only if the difference between the selected and actual temperature is over 20°C.
9.5 OPERATION WITH ROOM PROBE ON THE BOILER
The boiler can be switched on/off manually or in programmed mode.
the boiler (that is, the boiler attempts to maintain the desired temperature while minimising fuel consumption).
If the user has enabled the “Eco-mode” function under submenu
[7] of the setup menu , the boiler
rather than modulating its output, switches off when reaching the set temperature, and switches on again
when the room temperature falls below the delta set in submenu
[7] of the setup menu .
The desired room temperature can be set in temperature menu
.
Submenu
[6] of the setup menu can be used to set the desired water outlet temperature (the best temperature
for the heating system in question should be suggested by the heating system installer).
9.6 OPERATION IN COMBINATION WITH A STORAGE TANK
whether the storage tank is with or without a coil inside.
The boiler is controlled based on the temperature read by the probe in the storage tank.
When reaching the storage tank temperature set in the temperature menu
the boiler switches off, and
switches on again if the temperature falls below the delta set in submenu
[8] of the setup menu .
"#