Check for broken power wire in release valve cable:
Unplug connector at valve.
Set multimeter to read DC voltage.
Put positive lead of multimeter in plug.
Put negative lead of multimeter in other hole of
plug.
Activate down function on gate.
Preferred reading should be 10V or higher.
Check for broken wire in release valve cable:
Set multimeter to OHM function.
Place a test lead of the multimeter at each end of
the wire.
If there is resistance in the wire, then the
continuity test is positive and will show a value
on the multimeter.
If the amount of resistance shows zero (0), then
the wire is broken.
Power Cable to Release Valve Coil Test