3-11
Measuring
Measuring point (
*
)
No. Item instruments & Mode
Adjustment parts (
-
)
Adjustment procedure
Input signals
Adjustment level (
+
)
10 NTSC LINE IN
REC C level
adjustment
(SETUP OFF)
WFM (NTSC) or
oscilloscope
LINE IN.
NTSC 100%
color bar
(SETUP 0%)
EE
ADJUST
MENU, 220.
LE REC C LEV
(S OFF)
(1) Set the INPUT SELECT SW to LINE or Y/C.
(2) Select ADJUST MENU No. 220, "LE REC C LEV
(S OFF)".
(3) Adjust so that the RED color levels are as speci-
fied.
(4) Press the [SET] button to store the adjustment
data.
*
C OUT (Y/C jack) (75 !
terminated)
-
[PLAY] and [STOP]
buttons
+
908 mVp-p
(RED)
11 NTSC Y/C IN
EE Y level
adjustment
(SETUP OFF)
WFM (NTSC) or
oscilloscope
Y/C IN.
NTSC 100%
color bar
(SETUP 0%)
EE
ADJUST
MENU, 221.
YC EE Y LEV
(S OFF)
(1) Set the INPUT SELECT SW to LINE or Y/C.
(2) Select ADJUST MENU No. 221, "YC EE Y LEV
(S OFF)".
(3) Adjust so that the level from the pedes-
tal to 100% WHITE is as specified.
(4) Press the [SET] button to store the adjustment
data.
*
Y OUT (Y/C jack) (75 !
terminated)
-
[PLAY] and [STOP]
buttons
+
100 IRE
(714 mVp-p)
12 NTSC Y/C IN
EE C level
adjustment
(SETUP OFF)
WFM (NTSC) or
oscilloscope
Y/C IN.
NTSC 100%
color bar
(SETUP 0%)
EE
ADJUST
MENU, 222.
YC EE C LEV
(S OFF)
(1) Set the INPUT SELECT SW to LINE or Y/C.
(2) Select ADJUST MENU No. 222, "YC EE C LEV
(S OFF)".
(3) Adjust so that the burst levels are as speci-
fied.
(4) Press the [SET] button to store the adjustment
data.
*
C OUT (Y/C jack) (75 !
terminated)
-
[PLAY] and [STOP]
buttons
+
40 IRE
(286 mVp-p)
908mVp-p
100 IRE
(714mVp-p)
286mVp-p
40IRE
Reference:
If a 7.5% setup signal should be used, the
same effect as this adjustment can be ob-
tained by simply ignoring the setup level.
Reference:
If 7.5% signal setup should be used, the
same effect as this adjustment can be ob-
tained by adjusting the color level to 836
mV p-p (100% color).