3-16
Measuring
Measuring point (
*
)
No. Item instruments & Mode
Adjustment parts (
-
)
Adjustment procedure
Input signals
Adjustment level (
+
)
25 NTSC LINE IN
REC C level
adjustment
(SETUP ON)
WFM (NTSC) or
oscilloscope
LINE IN.
NTSC 100%
color bar
(SET UP 7.5 %)
EE
ADJUST
MENU, 240.
LE REC C LEV
(S ON)
(1) Set the INPUT SELECT SW to LINE or Y/C.
(2) Select ADJUST MENU No. 240, "LE REC C LEV
(S ON)".
(3) Adjust so that the RED color levels are as speci-
fied.
(4) Press the [SET] button to store the adjustment
data.
*
C OUT (Y/C jack) (75 !
terminated)
-
[PLAY] and [STOP]
buttons
+
836 mVp-p
(RED)
(1) Set the INPUT SELECT SW to LINE or Y/C.
(2) Select ADJUST MENU No. 241, "YC EE Y LEV
(S ON)".
(3) Adjust so that the level from the pedes-
tal to 100% WHITE is as specified.
(4) Press the [SET] button to store the adjustment
data.
(1) Set the INPUT SELECT SW to LINE or Y/C.
(2) Select ADJUST MENU No. 242, "YC EE C LEV
(S ON)".
(3) Adjust so that the burst levels are as speci-
fied.
(4) Press the [SET] button to store the adjustment
data.
26 NTSC Y/C IN
EE Y level
adjustment
(SETUP ON)
WFM (NTSC) or
oscilloscope
Y/C IN.
NTSC 100%
color bar (Setup
7.5%)
EE
ADJUST
MENU, 241.
YC EE Y LEV
(S ON)
*
Y OUT (Y/C jack) (75 !
terminated)
-
[PLAY] and [STOP]
buttons
+
100 IRE (714 mVp-p)
27 NTSC Y/C IN
EE C level
adjustment
(SETUP ON)
WFM (NTSC) or
oscilloscope
Y/C IN.
NTSC 100%
color bar
(Setup 7.5%)
EE
ADJUST
MENU, 242.
YC EE C LEV
(S ON)
*
C OUT (Y/C jack) (75 !
terminated)
-
[PLAY] and [STOP]
buttons
+
40 IRE
(286 mVp-p)
100 IRE
(714mVp-p)
836mVp-p
286mVp-p
40IRE