EasyManua.ls Logo

Panasonic Aquarea WH-ADC0309J3E5 - Page 83

Panasonic Aquarea WH-ADC0309J3E5
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
83
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Connections
b
b
c
c
d
a
Connection
PAW‑BTANK200L /
PAW‑BTANK300L
a Air purge valve 1/2″BSPPfemale
b Upper supply/return connection 1″BSPPfemale
c Lower supply/return connection 1″BSPPfemale
d Drain valve 1/2″BSPPfemale
Unit: Inches (")
Dimensions
B
30°
45°
150°
A
B
C
D
E
F
Dimension PAW‑BTANK200L PAW‑BTANK300L
A 1,340 1,820
B 1,275 1,755
C 941 1,421
D 301 301
E 155 155
F (Ø) 595 595
Unit: mm
Technical data
Buffer tanks
Model PAW‑BTANK50L‑2 PAW‑BTANK100L PAW‑BTANK200L PAW‑BTANK300L
Capacity l 48 100 199 289
Energy losses W 35 55 50 66
EnergyEfciencyClass(scalefromA+toF) B C B B
Material Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Dimension (Hight / Diameter) mm 636 / 430 1175 / 430 1275 / 595 1755 / 595
Net weight kg 17 28 47 57
Notes: Automatic air vent and drain cock are included. Built-in sensor pocket (sensor not included). Bu󰀨er Tanks are produced by OSO.