Do you have a question about the Panasonic AQUAREA WH-ADC0912K6E5AN and is the answer not in the manual?
Critical safety warnings, cautions, and explanation of symbols for proper unit handling.
Critical safety warnings and cautions specific to R32 refrigerant installation and operation.
Technical specifications for the WH-ADC0912K6E5AN Indoor Unit and WH-UXZ09KE5 Outdoor Unit.
Technical specifications for the WH-ADC0912K6E5AN Indoor Unit and WH-UXZ12KE5 Outdoor Unit.
Details on the location of controls and components within the indoor unit, including remote controller.
Details on the location of components within the outdoor unit.
Detailed wiring diagram for the indoor unit, showing component connections.
Detailed wiring diagram for the outdoor unit, showing component connections.
Electronic circuit diagram for the indoor unit, illustrating component layout and connections.
Electronic circuit diagram for the outdoor unit, illustrating component layout and connections.
Visual representation of the main and optional sub printed circuit boards for the indoor unit.
Visual representation of the main printed circuit board for the outdoor unit.
Guidelines for determining the minimum required floor area and ventilation for indoor unit installation.
Guidelines for selecting the best location, drilling, and installing the indoor unit.
Criteria for selecting the optimal installation location for the outdoor unit, considering environmental factors.
Information about R32 refrigerant, its environmental impact, and safety considerations.
Chemical and physical characteristics of R32 refrigerant compared to R410A and R22.
Overview of inverter control, water temperature settings, and heating/cooling modes.
Control logic for heating operation, including thermostat and heat mode.
Control logic for cooling operation, including thermostat and cool mode.
Automatic switching between heat and cool modes based on ambient and set temperatures.
Control logic for tank operation, including 3-way valve, heat pump, and heater control.
Safety controls for all operations, including time delay, current, and overheating protection.
Protection controls specific to heating operation, including outdoor air temperature.
Protection controls specific to cooling operation, including freeze prevention.
Instructions for removing the front and top plates of the unit for disassembly.
Procedures and checks required to perform a test run of the installed system.
Step-by-step guide for performing proper pump down procedures on the system.
Accessing maintenance functions like actuator check, test mode, sensor setup, and password reset.
Accessing custom settings such as cool mode, backup heater, and smart DHW parameters.
Guide to diagnosing malfunctions within the refrigeration cycle, including pressure and current measurements.
How to check, display, and delete error codes using the self-diagnosis function.
Comprehensive table listing error codes, their causes, and primary locations to verify for troubleshooting.
Instructions for removing the front and top plates of the unit for disassembly.
Instructions for disconnecting and removing electronic controllers and their associated wiring.
Heating and cooling characteristics at different outdoor air temperatures and piping lengths.
Exploded view and parts list for the indoor unit, detailing component identification.
Exploded view and parts list for the outdoor unit, detailing component identification.