17
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
EU Ecodesign Directive
The European Union’s Ecodesign Directive 2009/125/EG provides the framework for establishing
the determination of the EU-wide valid requirements applicable for the product design, with which
the environmental loads and the CO
2
-emission by energy consumption-related products are to be
reduced throughout their total life cycle. The Ecodesign Directive must be implemented in every EU
member state into national law (e.g. in Germany by the Energy consumption relevant products act
(EVPG 2008) or in Austria by the Ecodesign Ordinance (ODV 2007)).
8
9
10
11
12
1
2
3
5
4
6
7
WH-ADC0309H3E5B + WH-UD03HE5-1
A++
A+
X
X
X
11 15
16
19
17
20
21
18
12
13
a
b
c
d
14
Example of Product Energy label (left)
1 Manufacturer
2 Symbol for space heating function
3 Energyefciencyclassscaleforspaceheating
4 Energyefciencyclassforspaceheating
5 Sound power level indoors
6 Sound power level outdoors
7 Year of validity of the Regulation
8 Product name
9 Symbol for water heating function with indication of
theloadprole
10 Energyefciencyclassforwaterheating
11 Rated heating capacity (kW) for the three European
climate zones
12 Regulation number
Example of Package Energy Label (right)
11 Manufacturer and product name
12 Package system
13 Package options:
a Solar system
b Hot water tank
c Control
d Additional heat source (e.g. boiler)
14 Year of validity of the Regulation
15 Symbol for space heating function
16 Energyefciencyclassscaleforspaceheating
17 Energyefciencyclassforspaceheating
18 Symbol for domestic hot water function with indication
oftheloadprole
19 Energyefciencyclassscaleforwaterheating
20 Energyefciencyclassforwaterheating
21 Regulation number
25.03.2021, cH
- new energy label from EU-GCAT21v1 inserted (le)
- when creating a new package label (right) for
WH-ADC0309J3E5C+ WH-UD03JE5 using Panaso-
nic’s Label Generator, I still get an old label (year
2015) with energy eiciency class scale A+++ to G
(space and water). Help needed.
13.04.2021, cH
Could not find any newer package label, not even
on websites of other manufacturers. So I le it as
is.
27.02.2022, cH
no answer
According to this Ecodesign Directive (or ErP Directive - Energy related products), boilers and heat
pumps (among other heat generating devices), hot water tanks and domestic ventilation devices
must fulll product-specic minimum requirements in respect of the energy eciency. Moreover,
individual products as well as so called “packages” (e.g. heater plus controls) must be provided
with a product or package energy eciency label. Energy eciency is calculated according to
uniform criteria and indicated on the label as energy eciency class (A+++ to D for space heating,
A+ to F for water heating).
Economical and Environment-Friendly
More than 79 % of the end energy utilisation in the household is used for heating and domestic hot
water production. At the same time, the fuel prices (oil, gas, wooden pellets) are subject to high
price variations and are becoming more and more expensive.
On the other hand, with an Aquarea heat pump, up to 80 % cost-free ambient heat can be used.
Only the remaining component of 20 % power needs to be sourced for the operation of the heat
10.03.2021, cH
75% => 79% (cf. EU-GCAT20, p. 25)