26 Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Model code for standard indoor units (bi-bloc systems)
Device type
WH: Air-to-water
heat pump
Construction
S: Standard indoor unit (hydrokit of the
bi-bloc system)
Series
D: Aquarea High Performance, X: Aquarea T-CAP,
Q: Aquarea T-CAP Super Quiet, H: Aquarea HT
Operating mode
1
C: Heating and cooling, F: Heating only
Nominal
heating capacity
2
0305: 3 or 5 kW, 0709: 7 or 9 kW (for J generation)
09 to 16 (corresponds to 9 to 16 kW for H and F generation)
Device
generation
3
... F, H, J ...
Backup heater
capacity
3: 3 kW, 6: 6 kW, 9: 9 kW
Market E: Europe
Power supply 5: Single phase, 8: Three phase
Code element for
random use (not applicable for current model range)
WH S D C 0709 J 3 E 5
1 The models of the Aquarea HT series can only be used for heating mode and have no cooling function.
2 The available capacities di󰀨er according to the series. An overview is given in the model range (→ 1 Model range,
p. 8).
3 J generation requires refrigerant R32, H generation requires refrigerant R410A, F generation requires refrigerant R407C.
Model code for outdoor units (bi-bloc systems)
Device type WH: Air-to-water heat pump
Construction U: Outdoor unit (of the bi-bloc system)
Series
D: Aquarea High Performance, X: Aquarea T-CAP,
Q: Aquarea T-CAP Super Quiet, H: Aquarea HT
Nominal
heating capacity
1
03 to 16 (corresponds to 3 to 16 kW)
Device
generation
2
... F, H, J ...
Market E: Europe
Power supply 5: Single phase, 8: Three phase
Code element for
random use -1: Revised model version
WH U D 09 J E 5 ‑1
1 The available capacities di󰀨er according to the series. An overview is given in the model range (→ 1 Model range,
p. 8).
2 J generation requires refrigerant R32, H generation requires refrigerant R410A, F generation requires refrigerant R407C.