214 Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Appendix
215
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Appendix
Menu Standard setting Setting options /Display
Installer set-up Operational setting
6.1
Heating
Setting of different
temperatures for the heating
mode.
Water temp. set-point heating /
Summer shutdown /
T for heating mode /
Bivalence temp. of E-heating element
Water temp. set-point heating
Heating
Setting of whether the
supply temperature is to
be calculated according
to heating levels or to be
definitively set.
Water temperature set-point for heating Heating curve
X axis:
-5 °C, 15 °C
Y axis:
55 °C, 35 °C
Entry of 4 temperature
values.
(2 on the horizontal X
axis, 2 on the vertical
Y axis).
Temperature range for the X-axis: -15 °C to 15 °C, Y-axis: see below.
Temperature range for the Y-axis depends on the model:
1. Model WH-SDC: 20°C to 55°C
2. Model WH-SHF and E-heating element are activated: 25°C to 65°C
3. Model WH-SHF and E-heating element are not activated: 35°C to 65°C
4. Model WH-SXC/SQC: 20°C to 60°C
If a second heating circuit is present, the 4 temperature values must also be given for
heatC 2.
“HC 1“ and “HC 2“ are not shown in the display if the system only has one heating
circuit.
Water temperature set-point for heating Fixed value
35 °C
Inputting a fixed flow
temperature
The following input ranges are available:
1. Model WH-SDC: 20°C to 55°C
2. Model WH-SHF and E-heating element are activated: 25°C to 65°C
3. Model WH-SHF and E-heating element are not activated: 35°C to 65°C
4. Model WH-SXC/SQC: 20°C to 60°C
Summer shutdown
24 °C
Outside temperature
at which the heating is
switched off (summer
mode)
Menu Standard setting Setting options /Display
5.13
Fault alarm output
No
5.14
Power control
No
5.15
SG ready
No
Yes
120 %
Boost
(Stages 1 and 2)
of buffer tank and
domestic hot water tank
(in %)
5.16
Ext. switch for OU
No
5.17
Liquid
Selection as to whether water
or glycol is being used as the
heating medium.
Water
5.18
Heating/cooling scheme
No
5.19
Man. E-heating
For switching on the
emergency heating mode
manually (standard) or
automatically.
Man.
6 Installer set-up Operational setting
Setting the four operating
modes.
4 operating modes
Heating / cooling *
1,
*
2
/ Auto / Hot water tank
Menus
For installers
*1 The system is preset for operation without a cooling function. The cooling function can be activated by an authorised installer or service
partner.
*2 This display only appears if the cooling function is activated, i.e. if the cooling mode is available.