50 Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
51
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
Compact system / T-CAP model series / H Generation
T-CAP model series Single-phase (230 V / 50 Hz), Heating and Cooling Three-phase (400 V / 50 Hz), heating and cooling
Compact device WH-MXC09H3E5 WH-MXC12H6E5 WH-MXC09H3E8 WH-MXC12H9E8 WH-MXC16H9E8
Model B9 B9 B9 B9 B9
Heatingcapacityat+7°C(A7/W35) kW 9.00 12.00 9.00 12.00 16.00
COPat+7°C(A7/W35) 4.84 4.74 4.84 4.74 4.28
Heatingcapacityat+2°C(A2/W35) kW 9.00 12.00 9.00 12.00 16.00
COPat+2°C(A2/W35) 3.59 3.44 3.59 3.44 3.10
Heating capacity at -7 °C (A–7/W35) kW 9.00 12.00 9.00 12.00 16.00
COP at -7 °C (A–7/W35) 2.85 2.72 2.85 2.72 2.49
Energyefciencyclass
1
at 35 / 55 °C
i / i i / i i * / i i * / i i * / i
Cooling capacity at 35 °C (A35/W7) kW 7.00 10.00 7.00 10.00 12.20
EER(energyefciencyratio)at35°C(A35/W7) 3.17 2.81 3.17 2.81 2.56
Sound pressure level Heating / Cooling dB(A) 51 / 49 52 / 50 51 / 49 52 / 50 55 / 54
Sound power (A7/W55) Heating / Cooling dB(A) 68 / 67 69 / 68 68 / 67 69 / 68 72 / 72
Dimensions HxLxW mm 1,410 x 1,283 x 320 1,410 x 1,283 x 320 1,410 x 1,283 x 320 1,410 x 1,283 x 320 1,410 x 1,283 x 320
Weight kg 148 148 155 155 168
Water-side connection mm 28 28 28 28 28
Highefciencypump
Rotation speed stages Variable Variable Variable Variable Variable
Powerconsumption(min./max.)
W 32 / 102 34 / 110 32 / 102 34 / 110 38 / 120
Waterowrate(A7/W35) l/min 25.8 34.4 25.8 34.4 45,9
Power of E-heating element kW 3 6 3 9 9
Power consumption Heating / Cooling kW 1.86/2.21 2.53/3.56 1.86/2.21 2.533.56 3.74/4.76
Operating and start up current Heating / Cooling A 8.6/10.2 11.7/16.5 2.8/3.4 3.8/5.3 5.7/7.2
Max.powerconsumptiononnetworkconnection1/2 A 25.0/13.0 29.0/26.0 14.7/13.0 11.9/13.0 15.5/13.0
Recommended fuse for network connection 1 / 2 A 30 / 30 30 / 30 16 / 16 16 / 16 16 / 16
Recommended cable cross section for network connection 1 / 2
mm² 3x4.0or6.0/3x4.0 3x4.0or6.0/3x4.0 5x1.5/3x1.5 5x1.5/5x1.5 5x1.5/5x1.5
Pre-lledrefrigerant(R410A)/CO
2
-equivalent kg / t CO
2
-Equ. 2.3/4.802 2.3/4.802 2.3/4.802 2.3/4.802 2.35/4.907
Operating range Outside temperature (H / K) °C -20 to 35 / 16 to 43 -20 to 35 / 16 to 43 -20 to 35 / 16 to 43 -20 to 35 / 16 to 43 -20 to 35 / 16 to 43
Water outlet temperature (H / K)
°C 25 to 55 / 5 to 20 25 to 55 / 5 to 20 25 to 55 / 5 to 20 25 to 55 / 5 to 20 25 to 55 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efciency classes is based on the ofcial ErP specications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efciency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efciency class scale from A++ to G.
All data is provisional.
4.6.3.3 Technical Data
Compact system / LT series / H generation
LT series Single-phase (230 V / 50 Hz), Heating and Cooling
Compact device WH-MDC05H3E5 WH-MDC07H3E5 WH-MDC09H3E5
Model B8 B8 B8
Heatingcapacityat+7°C(A7/W35) kW 5.00 7.00 9.00
COPat+7°C(A7/W35) 5.08 4.46 4.15
Heatingcapacityat+2°C(A2/W35) kW 4.80 5.00 7.45
COPat+2°C(A2/W35) 3.75 3.45 3.14
Heating capacity at -7 °C (A–7/W35) kW 4.50 5.15 7.70
COP at -7 °C (A–7/W35) 2.98 2.68 2.12
Energyefciencyclass
1
at 35 / 55 °C
i * / i i * / i i * / i
Cooling capacity at 35 °C (A35/W7) kW 4.50 5.50 7.00
EER(energyefciencyratio)at35°C(A35/W7) 3.33 2.74 2.44
Sound pressure level Heating / Cooling dB(A) 49 / 47 49 / 47 51 / 49
Sound power (A7/W55) Heating / Cooling dB(A) 65 / 65 65 / 65 69 / 67
Dimensions HxLxW mm 865 x 1,283 x 320 865 x 1,283 x 320 865 x 1,283 x 320
Weight kg 107 112 112
Water-side connection mm 28 28 28
Highefciencypump
Rotation speed stages Variable Variable Variable
Powerconsumption(min./max.)
W 34 / 96 36 / 100 39 / 108
Waterowrate(A7/W35) l/min 14.3 17.2 25.8
Power of E-heating element kW 3 3 3
Power consumption Heating / Cooling kW 0.985/1.35 1.34/2.01 2.17/2.87
Operating and start up current Heating / Cooling A 4.5/6.1 6.1/9.3 9.9/13.0
Max.powerconsumptiononnetworkconnection1/2 A 19.5/13.0 20.5/13.0 22.9/13.0
Recommended fuse for network connection 1 / 2 A 30 / 15 30 / 15 30 / 16
Recommended cable cross section for network connection 1 / 2
mm² 3x4.0or6.0/3x4.0 3x4.0or6.0/3x4.0 3x4.0or6.0/3x4.0
Pre-lledrefrigerant(R410A)/CO
2
-equivalent kg / t CO
2
-Equ. 1.42/– 1.42/– 1.42/–
Operating range
Outside temperature (H / K) °C -20 to 35 / 16 to 43 -20 to 35 / 16 to 43 -20 to 35 / 16 to 43
Water outlet temperature (H / K)
°C 20 to 55 / 5 to 20 20 to 55 / 5 to 20 20 to 55 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efciency classes is based on the ofcial ErP specications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efciency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efciency class scale from A++ to G.