72 Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
73
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
PAW-TG30C2E3STD-1
A
B K L
C
F
E
G
D
H
b
c
1
c
2
d
h
2
h
1
i
Dimensions PAW-TG30C2E3STD-1
A 1,450
B 250
C 370
D 740
E 800
F 1,205
G 400
H (Ø) 760
K 225
L 425
Unit: mm
4.8.1.5 Technical Data
Domestic hot water tank Standard hot water tank (stainless steel) High performance hot water tank (enamelled) Domestic hot water tank
(enamelled) with 2 heat
exchangers
(bivalent: Solar + HP)
Model PAW-TD20C1E5
1
PAW-TD30C1E5
1
PAW-TG20C1E3STD-1 PAW-TG30C1E3STD-1 PAW-TG40C1E3STD-1 PAW-TG30C2E3STD-1
Tank volume l 192 280
185 285 396 284
Max.watertemperature °C 75 75
95 95 95 95
Dimensions Height / Diameter mm 1265 / 595 1,745 / 595
1,535 / 580 1,590 / 680 1,950 / 750 1,300 / 750
Weight(net/incl.waterlling) kg 53 / – 65 /
97 / 282 140 / 425 171 / 567 134 / 418
Pivot measurement mm NA NA 1,641 1,729 2,089 1,501
Colour white white White aluminium White aluminium White aluminium White aluminium
Power of E-heating element kW 1.5 1.5 3 3 3 3
Power supply V 230 230 230 230 230 230
Material of the tank interior Stainless steel Stainless steel Enamelled Enamelled Enamelled Enamelled
Heat exchanger surface 1.8 1.8 2.0 2.5 6.1 2.4(forWP)++1(forsolar
or burner)
Standby loss at 65 °C
2
kWh/24 h 0.99 1.13 1.6 2.1 1.7 1.6
Connectionforcirculationline(3/4”) NA NA Yes Yes Yes Yes
Charging time Rating
★★★★ ★★★★ ★★★ ★★★ ★★★ ★★★
Energy losses Rating
★★★★ ★★★★ ★★★ ★★★ ★★★ ★★★
Heat loss W 64 83 70,8 88.8 71.9 68
Energyefciencyclass
3
a a c c b b
Guarantee 2 years 2 years 2 years 2 years 2 years 2 years
Maintenance required no no Annual Annual Annual Annual
1 thermostat included in the scope of delivery
2 Insulation tested according to EN 12897
3 Energy efciency class scale from A to G.
4.8.1.4 Dimensions
Dimensions PAW-TD20C1E5 PAW-TD30C1E5
PAW-TG20C1
E3STD-1
PAW-TG30C1
E3STD-1
PAW-TG40C1
E3STD-1
PAW-TG30C2
E3STD-1
A 1,265 1,745 1,535 1,590 1,920 1,450
B 157 157 180 175 250 250
C 268 268 300 270 370 370
D 678 868 880 890 1,070 740
E 780 740 990 800
F 1,265 1,265 1,355 1,410 1,675 1,205
G 365 320 400 400
H (Ø) 595 595 580 680 760 760
K 225
L 425
Unit: mm
PAW-TD20C1E5 / PAW-TD30C1E5
A
B
C
D
F
H
b
i
h
c
Dimensions PAW-TD20C1E5 PAW-TD30C1E5
A 1,265 1,745
B 157 157
C 268 268
D 678 868
F 1,265 1,265
H (Ø) 595 595
Unit: mm
PAW-TG20C1E3STD-1 / PAW-TG30C1E3STD-1 / PAW-TG40C1E3STD-1
A
B
C
F
E
G
D
H
b
c
d
h
i
Dimensions
PAW-TG20C1
E3STD-1
PAW-TG30C1
E3STD-1
PAW-TG40C1
E3STD-1
A 1,535 1,590 1,920
B 180 175 250
C 300 270 370
D 880 890 1,070
E 780 740 990
F 1,355 1,410 1,675
G 365 320 400
H (Ø) 580 680 760
Unit: mm