118 Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Planning
119
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Planning
Aquarea T-CAP, combination hydro-module, single- phase, Heating and cooling (ADC), Generation H
WH-ADC1216H6E5 / WH-UX09HE5
t
V
(°C) 30 35 40 45 50 55
t
a
(°C) P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP
25 13.60 1.50 9.07 13.60 1.71 7.95 13.20 1.93 6.84 12.80 2.14 5.98 12.00 2.41 4.98 11.20 2.67 4.19
7 9.00 1.64 5.49 9.00 1.86 4.84 9.00 2.16 4.17 9.00 2.46 3.66 9.00 2.76 3.26 9.00 3.06 2.94
2 9.00 2.36 3.81 9.00 2.51 3.59 9.00 2.78 3.24 9.00 3.05 2.95 9.00 3.56 2.53 9.00 4.07 2.21
-7 9.00 2.71 3.32 9.00 3.16 2.85 9.00 3.62 2.49 9.00 4.07 2.21 9.00 4.27 2.11 9.00 4.46 2.02
-15 9.00 3.24 2.78 9.00 3.51 2.56 9.00 3.91 2.30 9.00 4.30 2.09 9.00 4.73 1.90 9.00 5.16 1.74
WH-ADC1216H6E5 / WH-UX12HE5
t
V
(°C) 30 35 40 45 50 55
t
a
(°C) P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP
25 13.60 1.55 8.77 13.60 1.76 7.73 13.40 2.10 6.38 13.20 2.43 5.43 12.60 2.66 4.74 12.00 2.89 4.15
7 12.00 2.18 5.50 12.00 2.53 4.74 12.00 2.96 4.05 12.00 3.39 3.54 12.00 3.78 3.17 12.00 4.16 2.88
2 12.00 3.19 3.76 12.00 3.49 3.44 12.00 3.87 3.10 12.00 4.25 2.82 12.00 4.86 2.47 12.00 5.47 2.19
-7 12.00 3.85 3.12 12.00 4.41 2.72 12.00 4.98 2.41 12.00 5.54 2.17 12.00 5.90 2.03 12.00 6.26 1.92
-15 12.00 4.75 2.53 12.00 4.96 2.42 12.00 5.17 2.22 11.00 5.38 2.04 10.80 5.82 1.86 10.50 6.26 1.68
Aquarea T-CAP, combination hydro-module, Three-phase, Heating and cooling (ADC), Generation H
WH-ADC0916H9E8 / WH-UX09HE8 or WH-ADC0916H9E8 / WH-UQ09HE8
t
V
(°C) 30 35 40 45 50 55
t
a
(°C) P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP
25 13.60 1.50 9.07 13.60 1.71 7.95 13.20 1.93 6.84 12.80 2.14 5.98 12.00 2.41 4.98 11.20 2.67 4.19
7 9.00 1.64 5.49 9.00 1.86 4.84 9.00 2.16 4.17 9.00 2.46 3.66 9.00 2.76 3.26 9.00 3.06 2.94
2 9.00 2.36 3.81 9.00 2.51 3.59 9.00 2.78 3.24 9.00 3.05 2.95 9.00 3.56 2.53 9.00 4.07 2.21
-7 9.00 2.71 3.32 9.00 3.16 2.85 9.00 3.62 2.49 9.00 4.07 2.21 9.00 4.27 2.11 9.00 4.46 2.02
-15 9.00 3.24 2.78 9.00 3.51 2.56 9.00 3.91 2.30 9.00 4.30 2.09 9.00 4.73 1.90 9.00 5.16 1.74
WH-ADC0916H9E8 / WH-UX12HE8 or WH-ADC0916H9E8 / WH-UQ12HE8
t
V
(°C) 30 35 40 45 50 55
t
a
(°C) P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP
25 13.60 1.55 8.77 13.60 1.76 7.73 13.40 2.10 6.38 13.20 2.43 5.43 12.60 2.66 4.74 12.00 2.89 4.15
7 12.00 2.18 5.50 12.00 2.53 4.74 12.00 2.96 4.05 12.00 3.39 3.54 12.00 3.78 3.17 12.00 4.16 2.88
2 12.00 3.19 3.76 12.00 3.49 3.44 12.00 3.87 3.10 12.00 4.25 2.82 12.00 4.86 2.47 12.00 5.47 2.19
-7 12.00 3.85 3.12 12.00 4.41 2.72 12.00 4.98 2.41 12.00 5.54 2.17 12.00 5.90 2.03 12.00 6.26 1.92
-15 12.00 4.75 2.53 12.00 4.96 2.42 12.00 5.41 2.22 12.00 5.86 2.05 11.80 6.24 1.89 11.10 6.62 1.68
WH-ADC0916H9E8 / WH-UX16HE8 or WH-ADC0916H9E8 / WH-UQ16HE8
t
V
(°C) 30 35 40 45 50 55
t
a
(°C) P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP
25 16.00 2.02 7.92 16.00 2.58 6.20 16.00 2.90 5.52 16.00 3.36 4.76 16.00 3.74 4.27 16.00 4.00 4.00
7 16.00 3.35 4.77 16.00 3.74 4.28 16.00 4.30 3.75 16.00 4.80 3.33 16.00 5.43 2.95 16.00 5.91 2.71
2 16.00 4.67 3.43 16.00 5.21
3.10 16.00 5.74 2.79 16.00 6.31 2.54 16.00 6.99 2.31 16.00 7.50 2.13
-7 16.00 5.85 2.74 16.00 6.42 2.49 16.00 7.00 2.29 16.00 7.57 2.11 16.00 8.10 1.97 16.00 8.62 1.86
-15 16.00 6.30 2.54 16.00 6.89 2.32 16.00 7.50 2.13 16.00 8.10 1.98 16.00 8.48 1.89 15.20 8.96 1.70
Performances of split systems with combination hydro-module in cooling mode
Aquarea LT, combination hydro-module, single- phase, heating and cooling (ADC), Generation H
WH-ADC0309H3E5(B) / WH-UD03HE5-1 WH-ADC0309H3E5(B) / WH-UD05HE5-1
t
V
(°C) 7 14 18 7 14 18
t
a
(°C) P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER
43 2.90 1.20 2.42 3.50 1.20 2.92 3.00 0.88 3.41 3.30 1.53 2.16 4.10 1.52 2.70 4.40 1.53 2.88
35 3.20 1.04 3.08 3.90 1.07 3.64 3.30 0.74 4.46 4.50 1.67 2.69 5.50 1.68 3.27 5.00 1.33 3.76
25 3.20 0.73 4.38 4.10 0.86 4.77 3.50 0.59 5.93 5.00 1.43 3.50 6.30 1.50 4.20 5.40 1.06 5.09
18 2.40 0.42 5.71 4.40 0.73 6.03 3.70 0.49 7.55 4.50 0.89 5.06 5.00 0.90 5.56 5.70 0.90 6.33
WH-ADC0309H3E5(B) / WH-UD07HE5-1 WH-ADC0309H3E5(B) / WH-UD09HE5-1
t
V
(°C) 7 14 18 7 14 18
t
a
(°C) P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER
43 4.85 2.65 1.83 6.00 2.82 2.13 4.80 1.98 2.42 5.20 2.85 1.83 6.99 3.84 1.82 5.60 2.55 2.20
35 6.00 2.28 2.63 6.60 2.48 2.66 6.00 1.68 3.57 7.99 2.88 2.77 7.60 3.20 2.38 7.00 2.15 3.26
25 7.00 1.90 3.68 8.47 1.78 4.76 6.00 1.27 4.72 7.85 2.40 3.27 10.20 2.46 4.15 7.00 1.77 3.96
16 4.80 0.80 6.0 7.20 1.16 6.21 6.00 1.13 5.31 5.40 1.00 5.40 8.40 1.62 5.19 7.00 1.61 4.25
WH-ADC1216H6E5 / WH-UD12HE5 WH-ADC1216H6E5 / WH-UD16HE5
t
V
(°C) 7 14 18 7 14 18
t
a
(°C) P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER
43 7.80 3.80 2.05 11.10 3.19 3.48 8.00 2.85 2.81 7.75 3.40 2.28 13.80 5.95 2.32 9.70 4.00 2.43
35 10.00 2.56 3.91 12.00 2.67 4.49 10.00 2.40 4.17 12.20 4.76 2.56 15.00 4.98 3.01 12.20 2.96 4.12
25 12.08 2.90 4.17 15.70 2.05 7.66 10.00 1.97 5.07 14.40 3.92 3.67 19.20 3.83 5.01 12.20 2.79 4.37
16 7.86 1.18 6.66 13.15 1.40 9.39 10.00 1.73 5.78 9.20 1.62 5.68 16.40 2.58 6.36 12.20 2.45 4.98
Aquarea LT, Combination hydro-module, Three-phase, Heating and cooling (ADC), Generation H
WH-ADC0916H9E8 / WH-UD09HE8 WH-ADC0916H9E8 / WH-UD12HE8
t
V
(°C) 7 14 18 7 14 18
t
a
(°C) P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER
43 5.52 2.54 2.17 7.69 2.77 2.78 5.60 1.80 3.11 7.80 3.80 2.05 11.10 3.19 3.48 8.00 2.85 2.81
35 7.00 2.23 3.14 8.30 2.32 3.58 7.00 1.52 4.61 10.00 2.56 3.91 12.00 2.67 4.49 10.00 2.40 4.17
25 8.35 1.77 4.72 10.90 1.78 6.12 7.00 1.24 5.65 12.08 2.90 4.17 15.70 2.05 7.66 10.00 1.97 5.08
16 7.50 1.15 6.52 9.10 1.20 7.58 8.00 1.13 7.08 7.86 1.18 6.66 13.15 1.40 9.39 10.00 1.73 5.78
WH-ADC0916H9E8 / WH-UD16HE8
t
V
(°C) 7 14 18
t
a
(°C) P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER
43 7.75 3.40 2.28 13.80 5.95 2.32 9.70 4.00 2.43
35 12.20 4.76 2.56 15.00 4.98 3.01 12.10 2.96 4.09
25 14.40 3.92 3.67 19.20 3.83 5.01 12.20 2.79 4.37
16 9.20 1.62 5.68 16.40 2.58 6.36 12.20 2.45 4.98
Aquarea T-CAP, combination hydro-module, single- phase, Heating and cooling (ADC), Generation H
WH-ADC1216H6E5 / WH-UX09HE5 WH-ADC1216H6E5 / WH-UX12HE5
t
V
(°C) 7 14 18 7 14 18
t
a
(°C) P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER
43 7.80 3.80 2.05 11.10 3.19 3.48 8.00 2.85 2.81 7.75 3.40 2.28 13.80 5.95 2.32 9.70 4.00 2.43
35 10.00 2.56 3.91 12.00 2.67 4.49 10.00 2.40 4.17 12.20 4.76 2.56 15.00 4.98 3.01 12.20 2.96 4.12
25 12.08 2.90 4.17 15.70 2.05 7.66 10.00 1.97 5.07 14.40 3.92 3.67 19.20 3.83 5.01 12.20 2.79 4.37
16 7.86 1.18 6.66 13.15 1.40 9.39 10.00 1.73 5.78 9.20 1.62 5.68 16.40 2.58 6.36 12.20 2.45 4.98
Aquarea T-CAP, combination hydro-module, Three-phase, Heating and cooling (ADC), Generation H
WH-ADC0916H9E8 / WH-UX09HE8 WH-ADC0916H9E8 / WH-UX12HE8
t
V
(°C) 7 14 18 7 14 18
t
a
(°C) P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER
43 6.25 2.66 2.35 – – – – – – 8.00 3.01 2.66 – – – – – –
35 7.00 2.21 3.17 – – – – – – 10.00 3.56 2.81 – – – – – –
25 7.65 1.91 4.01 – – – – – – 8.90 2.16 4.12 – – – – – –
18 7.00 1.36 5.15 – – – – – – 7.50 1.41 5.32 – – – – – –
WH-ADC0916H9E8 / WH-UX16HE8
t
V
(°C) 7 14 18
t
a
(°C) P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER P
Klg
(kW) P
zu
(kW) EER
43 7.10 3.31 2.15 – – – 9.80 3.31 2.96
35 12.20 4.76 2.56 – – – 12.20 3.50 3.49
25 14.00 4.00 3.50 – – – 14.00 2.94 4.76
18 8.50 1.70 5.00 – – – 10.00 1.70 5.88
Performances of split systems with hydro-module in heating mode
Aquarea LT, Split, single- phase, Heating and Cooling (SDC), Generation H
WH-SDC03H3E5-1 / WH-UD03HE5-1
t
V
(°C) 30 35 40 45 50 55
t
a
(°C) P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP
25 3.20 0.42 7.62 3.20 0.46 6.96 3.20 0.55 5.82 3.20 0.63 5.08 3.20 0.73 4.38 3.20 0.82 3.90
7
3.20 0.58 5.52 3.12 0.64 4.88 3.20 0.77 4.16 3.20 0.89 3.60 3.20 1.05 3.05 3.20 1.20 2.67
2
3.20 0.82 3.90 3.29 0.90 3.66 3.20 1.03 3.11 3.20 1.16 2.76 3.20 1.33 2.41 3.20 1.49 2.15
-7
3.20 1.08 2.96 3.58 1.19 3.00 3.20 1.34 2.39 3.20 1.48 2.16 3.20 1.67 1.92 3.20 1.86 1.72
-15
3.20 1.26 2.54 3.13 1.39 2.25 3.10 1.52 2.04 3.00 1.64 1.83 2.80 1.78 1.57 2.75 1.92 1.43
WH-SDC05H3E5-1 / WH-UD05HE5-1
t
V
(°C) 30 35 40 45 50 55
t
a
(°C) P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP P
Hzg
(kW) P
zu
(kW) COP
25 5.00 0.74 6.76 5.00 0.82 6.10 5.00 1.02 4.90 5.00 1.22 4.10 5.00 1.35 3.70 5.00 1.49 3.36
7
5.00 0.97 5.15 5.00 1.08 4.63 5.00 1.28 3.91 5.00 1.48 3.38 5.00 1.68 2.98 5.00 1.89 2.65
2
4.20 1.22 3.44 4.20 1.35 3.11 4.20 1.50 2.80 4.20 1.65 2.55 4.15 1.86 2.23 4.10 2.07 1.98
-7
4.20 1.46 2.88 4.20 1.62 2.59 4.00 1.72 2.33 3.80 1.82 2.09 3.70 1.95 1.90 3.55 2.08 1.71
-15
4.20 1.75 2.40 4.20 1.94 2.17 3.80 1.96 1.94 3.40 1.98 1.72 3.20 2.05 1.56 3.00 2.12 1.42