EasyManua.ls Logo

Panasonic BP-5917C40 - Overcharge Protection Circuits and Distribution Panels; General Information; Features; Specifications

Panasonic BP-5917C40
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Panasonic Solar Cells Handbook, Page 35 August 1998
11. OVERCHARGE PROTECTION CIRCUITS: DISTRIBUTION PANELS
Suitable for highly reliable power supplies
11.1. General Information
The "overcharge protection units" consists only of
overcharge protection circuits configured as a unit.
Being relatively low-cost, the unit is ideal for systems
which do not require testing.
These distribution panels distribute the power generated
by solar modules to storage batteries and loads. The
measuring circuitry provided makes it possible to test
the output current, output voltage, storage battery
voltage and load current of the solar modules. The
panels are also provided with overcharge prevention
circuits to protect the storage batteries from
overcharging.
11.2 Features
Excellent reliability.
Low current consumption.
Lightweight
Easy wiring and operation
11.3
Specifications
Overcharge protection unit
Model No. Storage battery used
Operating
voltage (V)
Return voltage
(V)
Maximum allowable
input curre nt
External view and
parts diagram No.
BP-H3CCUL
Lead storage battery *
Alkaline storage battery
14.5 15.5 13.5 14.5
37
BP-H10CCUL 10 8
Discharge protection unit
Model No.
Type of Battery
Used
Overcharge
Prote ction
Circuit
Operating
Voltage (V)
Overcharge
Prote ction
Circuit
Restore
Voltage (V)
Overdischarge
Prote ction
Circuit
Operating
Voltage (V)
Overdischarge
Prote ction
Circuit
Restore
Voltage (V)
Maximum
Allowable
Input
Current (A)
External View
and Parts
Diagram No.
BP-CD10A12V Lead storage battery 14.5 13.5 10.8 12.8 10 9
Measurement Items and meter full-scale levels
Model No.
Measurement items and meter full-scale levels Maximum
allowable
input
current
External view
and parts
diagram No.
Solar modules
output current (A)
Solar modules
output voltage
(V)
Load
current (A)
Awaite d
current (mA)
Storage
batte ry
voltage (V)
BP-H3RCL 3 30 10 60 30 3 10
BP-H10RCL 10 30 30 600 30 10 11
* The suffix “L” is eliminated from model numbers when lead storage batteries aren't used for
distribution panels equipped with an overcharge protection circuit or for overcharge protection
units.

Related product manuals