- Refer to the circuit diagram for the connection locations for each
thermistor.
- If there is an abnormality in the room temperature thermistor, the
temperature will be fixed at 25°C regardless of the remote control
display.
NOTE:
- Any abnormalities detected by the temperature thermistors are
ignored during emergency operation, therefore, long-term
operation in this mode should be avoided.
- After emergency mode operation has been completed and normal
operation is to be resumed, turn off the power supplies for the
indoor and outdoor units and set the DSW1 switch to NORMAL
position.
- Self-diagnosis LEDs 4 to 6 will flash during emergency operation.
27. CONTROL
Description of basic Functions
27.1. Cooling mode operation time chart