position (angle 0°).
C. Cancelling
Hot starting will be cancelled when the compressor is turned on
or the indoor unit pipe temperature sensor is 18°C or higher or
after 1 minute of operation.
After cancellation, the “PREHEAT” display on the remote
control disappears and the louvre operation returns to the
previous setting.
(However, for 2 minutes after cancellation, the indoor unit fan
operates at LOW speed, and then returns to the previous
setting.)
<When hot start operation is cancelled by temperature>
<When hot start operation is cancelled by time>
2. When defrosting is completed
A. Start
Hot start control commences when defrosting is completed.
B. Operation
“PREHEAT” appears on the remote control display. (Other
displays remain unchanged)