operating at the fan speed set by the remote control unit. (The
remote control unit display does not change.)
2. Cancelling / This control is cancelled when the temperature
detected by the indoor unit pipe temperature sensor is 15°C or
higher. / (If the outdoor unit stops even though the temperature is
15°C or higher, restart prevention control will activated and the
outdoor unit will not start again for 3 minutes.) / (The 9-minute
countdown is cleared while the compressor is stopped.)
(The above illustration shows the operation when there are no
conditions for turning the outdoor unit off other than freezing
prevention.)
26.3. Heating mode operation time chart (Heat pump type only)