3. Cancelling / After 1 minute has passed since heating mode
operation started, or if the compressor has turned on, hot /
starting is cancelled when the temperature detected by the indoor
unit pipe temperature sensor is 18~C / or higher. / After
cancellation, the "PREHEAT" display on the remote control
disappears and the louvre operation / returns to the previous
setting. / (However, for 2 minutes after cancellation, the indoor
unit fan operates at LOW speed, and then returns to / the
previous setting.) / / <When hot start operation is cancelled by
temperature>
2. When defrosting is complete
1. Start / Hot start control commences when defrosting is complete.
2. Operation / "PREHEAT" appears on the remote control display.
(Other displays remain unchanged.) / At the indoor unit, the
indoor unit fan stops. In addition, during hot starting, the louvre
stays at the horizontal / position (angle 0~).