Compressor
Type, Number of Set - Hermetic-1 (
Starting Method - Direct on-line
Motor Type - 2-pole single
induction
Input kW - Cool/Heat 2.31/
Rated
Output
kW - 1.9
Fan Type, Number of Set Sirocco fan-2 Prop. fan-1
Air Volume Control Three-Step and Auto mode
-
(Remote Control)
Motor Type 4-pole single phase induction
motor
6-pole single
induction
Input kW 0.15 0.11
Rated
Output
kW 0.085 0.05
Air-heat Exchanger Louvre-fin type Louvre-fin
Refrigerant Control Capillary tube Capillary tube
Refrigerant Oil (Charged) L - MS32 (1.3)
Refrigerant (Charged) kg (oz) - R-22 2.5 (88)
Running
Adjustment
Control Switch Wired Remote Control -
Room Temperature Thermostat (Main Body) -
Safety Devices Internal protector for compressor, Internal
F.M, Crankcase heater, High pressure switch,
Transformer
Noise Level (Sound Pressure) dB (A) Hi 35 Lo 35 Cooling 50,
1. Cooling capacities are based on indoor temp. 27°C D.B (80.6°F
D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temp. 35°C D.B.
(95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temp. 20° CD.B (68.0°
FD.B.) and outdoor air temp. 7°C D.B. (44.6°F D.B.), 6°C W.B.
(42.8°F D.B.)
ELECTRICAL DATA (50Hz)