(For 8.5.8. to 8.5.14. information applies only to Heating Operation)
8.5.7. Anti-Dew Formation Control
Purpose is to prevent dew formation on indoor unit air discharge area.
When room temperature is constant (±1°C) the following conditions occur for 30 minutes continuously, anti-dew formation will
activate:
Remote Control setting temperature is less than 25°C.
Compressor is on.
Cooling operation mode.
Indoor Fan motor operate at Low fan speed (CLo, Lo- or QLo).
This control is cancelled immediately when above condition is changed, or Powerful button is pressed.
Anti-Dew formation is control by:
1. CLo fan is changed to HLo fan.
2. QLo fan is changed to HLo fan.
8.5.8. 30 Minutes Time Save Control
The compressor will start automatically if it has stopped for 30 minutes and the intake air temperature falls between the
compressor OFF temperature (A) and compressor ON temperature (B) during the period.
This is to maintain the room temperature as set. Despite of this, it is to prevent a wrong judgement of intake air temperature due
to poor installation near the sensor area.
25
CS-A7DKD CU-A7DKD / CS-A9DKD CU-A9DKD / CS-A12DKD CU-A12DKD /

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A7DKD and is the answer not in the manual?

Panasonic CS-A7DKD Specifications

General IconGeneral
BrandPanasonic
ModelCS-A7DKD
CategoryAir Conditioner
LanguageEnglish

Related product manuals