6
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Note:
• Specification are subjected to change without prior notice for further improvement.
Fan
Type Cross-flow Fan Propeller Fan
Material ASG20K1 PP Resin
Motor Type Induction (4-poles) Induction (6-poles)
Input power W 42 - 47 56 - 63
Output power W 15 30
Fan Speed
Lo (Cool / Heat) rpm 780 / 840 —
Me (Cool / Heat) rpm 920 / 920 —
Hi (Cool / Heat) rpm 1030 / 1200 800 - 830 / —
SHi (Cool / Heat) rpm 1200 / — —
Heat Exchanger
Fin material Aluminium (Pre Coat) Aluminium (Blue Coat)
Fin Type Slit Fin Corrugate Fin
Row × Stage × FPI 2 × 15 × 21 1 × 19 × 17
Size (W × H × L) mm (inch) 610 × 315 × 25.4 22 × 483 × 576
Air Filter Type
Material Polypropelene —
Style One-touch —
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single Single
V 220 230
Hz 50 50
Input power
Cooling W 610 630
Heating W 500 525
Starting Current A 12.4 12.4
Running Current Cooling A 2.9 2.8
Heating A 2.4 2.4
Maximum Current A 3.4 3.4
Power Factor
Cooling % 96 98
Heating % 95 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core 3 (1.5mm)
Length m (ft) 2 (6)
Thermostat ——
Protection Device — 2 Stage Overload Protector
Item Unit Indoor unit Outdoor unit