8.10. Powerful Mode Operation
Purpose of this operation is to be obtain the setting temperature quickly.
 1. 
Cooling and Soft Dry Mode
  • 
When the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting
temperature (Lower temperature: 16°C). This operation automatically will be running under SHi Fan speed (cooling), Lo-
Fan Speed (Soft Dry).
  • 
Vertical Airflow Direction:-
In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.
In “Auto” setting, the vane will automatically swing up and down. However the upper and lower limit will be shifted 10°
downward.
 2. 
Heating Mode
  • 
When the Powerful Mode is set, the set temperature will be automatically increased 3°C against the present setting
temperature (Higher temperature: 30°C).
  • 
The Fan Speed will shift as shown below:
  • 
Vertical Airflow Direction:-
In “Manual” setting, the vane will automatically shift down 5° lower than previous setting.
In “Auto” setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature as
Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5° downward.
 3. 
Powerful mode will operate for 15 minutes only.
 4. 
Powerful Mode will stop if:
  • 
Powerful mode button is pressed again.
  • 
Stopped by ON / OFF switch.
  • 
Timer-off activates.
  • 
Quiet mode button is pressed.
  • 
Operating mode is changed.
33
CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5