1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Note:
Specification are subjected to change without prior notice for further improvement.
Heat Exchanger
Fin material Aluminium (Pre Coat) Aluminium (Blue Coat)
Fin Type Slit Fin Corrugate Fin
Row × Stage × FPI 2 × 15 × 21 2 × 24 × 17
Size (W × H × L) mm (inch) 610 × 315 × 25.4 36.38 × 504 × 713:684
Air Filter Type
Material Polypropelene
Style One-touch
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single Single
V 220 230
Hz 50 50
Input power
Cooling W 1.08 1.12
Heating W 1.09 1.12
Starting Current A 20 20
Running Current Cooling A 5.1 5.1
Heating A 5.2 5.1
Maximum Current A 6.0 6.0
Power Factor
Cooling % 96 95
Heating % 95 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core 3 (1.5mm)
Length m (ft) 2 (6)
Thermostat ——
Protection Device Overload Protector
Item Unit Indoor unit Outdoor unit