53
14.3. Remote Control Button
14.3.1. SET BUTTON
To check current remote control transmission code.
- Press for more than 10 seconds.
To change the air quality sensor sensitivity:
- Press and release with pointer.
- Press the Timer Decrement button to select sensitivity:
1. Low Sensitivity
2. Standard (Default)
3. Hi Sensitivity
- Confirm setting by pressing Timer Set button, a “Beep” sound will be heard. LCD returns to original display after 2 seconds.
- LCD returns to original display if remote control does not operate for 30 seconds.
14.3.2. CLOCK BUTTON
To change the remote control’s time format.
- Press for more than 5 seconds.
14.3.3. RESET
To clear and restore the remote control setting to factory default.
- Press once to clear the memory.
14.3.4. TIMER
To change indoor unit indicator’s LED intensity.
- Press continuously for 5 seconds.
14.3.5. TIMER
To change remote control display from Degree Celsius (°C) to Degree Fahrenheit (°F).
- Press continuously for 10 seconds.