– 15 –
MAC9512086C2
CS-C181KE
Operation Details
2) Soft Dry Mode Operation
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote
Control, and then Soft Dry operation will start.
During Soft Dry operation, the Indoor Fan will operate and stop at 4-second intervals at low speed.
The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry opera-
tion is turned off, it stops for 6 minutes.
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during
compressor stops.)
When Automatic Fan Speed is selected at Remote Control during Soft Dry Operation.
Fan speed rotates at SLo and Lo speed.
Deodorizing Control.
* SLo: Indoor Fan rotates at 4-second intervals at low speed.
Time Delay Safety Control
Anti-Freezing Control
Indoor
Fan
COMP
stop stop
stop
SLo Lo SLo
ON ON
OFF
40" 40"6'
Automatic Fan Speed Mode
Untitled-2 6/19/00, 5:14 PM15