Table (a): Auto Operation Mode Setting
Mode Shift: Temperature Shift (K)
E9BKP E12BKP
Cooling/Soft Dry → Heating -2.0 -2.0
Heating → Cooling/Soft Dry +2.0 +2.0
Table (b): Outdoor Air Temperature Shifting
Mode: Outdoor Temperature, X (°C): Temperature Shift (K)
E9BKP E12BKP
Cooling/Soft Dry X 30 0.0 0.0
X<30 +0.5 +0.5
Heating X 9 0.0 0.0
5 X<9 +0.5 +1.0
1 X<5 +1.0 +1.5
X<1 +1.5 +2.0
Table (c): Powerful Mode Shifting
Mode: Period, X (min): Temperature Shift (K)
E9BKP E12BKP
Cooling X<20 -2.0 -2.0
X 20 0.0 0.0
Soft Dry X<20 -1.0 -1.0
X 20 0.0 0.0
Heating X<20 +3.5 +3.5
X 20 +3.5 +3.5
Table (d): Fan Speed Shifting
Mode: Fan Speed: Temperature Shift (K)
E9BKP E12BKP
Cooling All +1.5 +1.5
Soft Dry All +1.0 +1.0
Heating Lo +1.0 +1.0
Me-, Me, Me+, Hi, Auto +0.5 +0.5
Table (e): Start-Up Shifting
Mode within 60 Minutes from Start-up: Temperature Shift (K)
E9BKP E12BKP
Cooling/Soft Dry -1.0 -1.0
Heating +2.0 +2.0
Table (f): Soft Dry Mode Shifting
Mode: Temperature Shift (K)
E9BKP E12BKP
Soft Dry +1.0 +1.0
17