8.1. BASIC FUNCTION
8 Operation Details
Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes,
automatically adjust output power for maximum comfort always. In order to achieve the suitable operating mode, the
microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature
shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputer at indoor unit that
judging the condition according to internal setting temperature and intake air temperature.
8.1.1. Internal Setting Temperature
Once the operation starts, remote controller setting temperature will be taken as base value for temperature shifting processes.
These shifting processes are depending on the air conditioner settings and the operation environment. The final shifted value
will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit.
16
CS-E9BKP CU-E9BKP5 / CS-E12BKP CU-E12BKP5

Other manuals for Panasonic CS-E12BKP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E12BKP and is the answer not in the manual?

Panasonic CS-E12BKP Specifications

General IconGeneral
BrandPanasonic
ModelCS-E12BKP
CategoryAir Conditioner
LanguageEnglish

Related product manuals