9
English
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Single split outdoor unit
CU-E7PKD, CU-E9PKD, CU-E12PKD,
CU-E15PKD, CU-E18PKD, CU-E24PKD
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 43 26
Min. 16 11 16 11
HEAT
Max. 30 - 24 18
Min. 16 - -5 -6
°C (temperature)
Multi split outdoor unit
CU-2E15PBD, CU-2E18PBD, CU-4E27PBE,
CU-5E34PBE, U-3E18JBE, U-4E23JBE
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 46 26
Min. 16 11 -10 4
HEAT
Max. 30 - 24 18
Min. 16 - -15 -11
°C (temperature)
To learn more...
Sunlight Sensor operation
Set
temperature
HEAT
COOL/DRY
+1 °C
-1 °C -1 °C
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
The human activity sensor will also scan for area of heat source and movement in a room.
Detection area Human activity indicator
120º
7m
At left area At center / multiple area At right area
The unit judges human activity area for a few seconds before indicator updates. Based on area activeness
horizontal airfl ow direction louver will adjust either fi x at predetermined position or swing left/right periodically.
• The human activity sensor performance is infl uenced by indoor unit location, movement speed, temperature
range, etc.
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor’s detection
area. They may cause sensor malfunction.