2. Auto Fan Speed
Note:
a. UP:
If move from Lo, the fan speed will be shifted to Maximum 1300 rpm (E24CK).
If move from Maximum, the fan speed no change.
In up zone, 10 rpm is added for every 10s until Maximum 1300 rpm (E24CK).
b. DOWN:
The fan speed will be decreased one step every 10 sec. until Minimum 1100 rpm.
c. Current Output Fixed:
Maintain at present fan speed.
d. Instantaneous Maximum:
Fan speed will be increased to maximum auto fan speed.
e. Temperature in ( ) is for Powerful Mode operation.
8.2.3.2. Intake Air Temperature Control
Compressor will operate at freq 67 Hz if either one of the below conditions occur:
1. When the indoor intake air temperature is above 10°C and remote control setting fan speed is lower Me-.
2. When the indoor intake air temperature is 30°C or above.