28 
Drain Hose 
Inner Diameter  mm   16.7 
Length mm  650 
Indoor Heat 
Exchanger 
Fin Material    Aluminium (Pre Coat) 
Fin Type    Slit Fin 
Row x Stage x FPI    2 x 15 x 21 
Size (W x H x L)  mm  25.4 x 315 x 810 
Outdoor 
Heat 
Exchanger 
Fin Material    Aluminium (Blue Coated) 
Fin Type    Corrugated Fin 
Row x Stage x FPI    2 x 44 x 19 
Size (W x H x L)  mm  38.1 x 1117.6 x 863.8:833.8 
Air Filter 
Material   Polypropelene 
Type   One-touch 
Power Supply    Outdoor Power Supply 
Power Supply Cord  A  Nil 
Thermostat   Electronic Contol 
Protection Device    Electronic Contol 
  DRY BULB  WET BULB 
Indoor 
Operation 
Range 
Cooling 
Maximum °C  32  23 
Minimum °C  16  11 
Heating 
Maximum °C  30  - 
Minimum °C  16  - 
Outdoor 
Operation 
Range 
Cooling 
Maximum °C  46  26 
Minimum °C  5  4 
Heating 
Maximum °C  24  18 
Minimum °C  -15  -16 
1.  Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and 
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB) 
2.  Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F 
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3.  Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C 
4.  Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C 
5.  Specifications are subjected to change without prior notice for further improvement.