EasyManua.ls Logo

Panasonic CS-E7PKR - Page 94

Panasonic CS-E7PKR
205 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
94
13.13.3 Rhythmic Temperature Wave Operation
To further maximize the energy saving during ECONAVI or AUTO COMFORT operates at low activity level.
Start condition
o The unit is operates in Cool or Dry mode under ECONAVI or AUTO COMFORT operation, and
o Human activity sensor detects low activity level, and
o Neuro stable zone continuously for 60 minutes.
Stop condition
o Unit is off, or
o ECONAVI or AUTO COMFORT is off, or
o Human activity sensor detects high activity level or absent, or
Control contents
o When all start conditions complied, set temperature will shift accordingly as following:

Table of Contents

Other manuals for Panasonic CS-E7PKR

Related product manuals