8.1.2.2.2. Initial frequency determination
After a starting control end, initial frequency (absolute value) is determined and is immediately shift.
However, the domain of Fhmax is judged instantly.
8.1.2.2.3. Change frequency determination
When directions of Fhmax determined from mentioned initial frequency, (intake-setting) relativity control. Fhmax continued until (If
other directions came by protection control, priority is given there) room temperature is reached, it shifts to relative control after
moving to change frequency.
The following operation determines change frequency.
The Hzkirikae = present condition frequency *Inclines (calculation)
Inclination = Lapsed time to remote control attainment (min)
Inclination 0-30 30 - 60 60
Inclination coefficient 70% 90% 100%
1. The present frequency is real operation frequency.
2. When directions change come out by remote control after starting, calculation continued.
The time to room temperature attainment is calculated.
3. When remote control directions were changed before room temperature achieved and below room temperature attainment
temperature becomes
With initial frequency, it is considered as change frequency.
20
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E9DKDW and is the answer not in the manual?

Panasonic CS-E9DKDW Specifications

General IconGeneral
BrandPanasonic
ModelCS-E9DKDW
CategoryAir Conditioner
LanguageEnglish

Related product manuals