16.3. Sensible Capacity Chart
Condition
Indoor temperature : 27°C / 19°C
Outdoor temperature : 35°C / 24°C
● CS-E9EKEB CU-E9EKEB
230V Outdoor Temperature (°C)
Indoor wet bulb
temperature
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 2.58 1.96 0.54 2.41 1.88 0.58 2.24 1.80 0.62 2.04 1.71 0.67
19.0°C 2.60 0.59
19.5°C 2.83 2.05 0.55 2.65 1.97 0.59 2.46 1.89 0.63 2.24 1.80 0.68
22.0°C 3.09 2.12 0.56 2.88 2.04 0.60 2.68 1.97 0.64 2.44 1.88 0.70
● CS-E12EKEB CU-E12EKEB
230V Outdoor Temperature (°C)
Indoor wet bulb
temperature
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 3.47 2.63 0.84 3.24 2.52 0.91 3.02 2.43 0.97 2.74 2.30 1.05
19.0°C 3.50 0.92
19.5°C 3.81 2.76 0.86 3.56 2.65 0.92 3.31 2.55 0.99 3.01 2.43 1.07
22.0°C 4.15 2.86 0.87 3.88 2.75 0.94 3.61 2.65 1.01 3.28 2.53 1.08
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP - Input Power (kW)
58
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB