63
14.4 Remote Controller Room Temperature Thermoshift Control
14.4.1 Purpose
To prevent not enough or over supply of cooling and heating capacity by adjusting the Room Temperature
thermoshift by using remote controller.
Temperature can be adjusted are -3°C (-5.4°F), -2°C (-3.6°F), -1°C (-1.8°F), 0°C (0°F), 1°C (1.8°F), 2°C (3.6°F),
3°C (5.4°F)
Thermoshift adjusted by Remote controller will be stored into EEPROM and added into the final target setting
temperature.
Function selection added to enable and disable this control.
14.4.2 Control method
Heating mode (using remocon function 58)
Normal display mode
Press SW (t 0secs)
When SW pressed continuously for t 5secs to enter service zone
& press SW’s to choose function 58 (shift 0°C)
Range = -3°C/-2°C/-1°C/0°C/+1°C/+2°C/+3°C
Transmit shift code
Timer Up Down button
Shift -3°C Shift -1°C
Shift 0°C
Shift +1°C
Shift +3°C
1 Press
SW, special setting is immediately cancelled and normal mode starts.
2 If no SW is pressed for 30secs, then special setting mode is cancelled and normal mode starts.
3 Under this function, only
, , & SW’s are effective.