18
Operation mode
AUTO : During operation, the POWER indicator will blinks at initial.
Unit selects operation mode every 10 minutes according to the setting and room
temperatures.
HEAT : The POWER indicator blinks at the initial stage of this operation. Unit takes a while
to warm up.
For system which HEAT mode has been locked, if operation mode other than
HEAT is selected, the indoor unit stops and the POWER indicator blinks.
COOL : Provides ef cient comfort cooling to suit your needs.
DRY : Unit operates at low fan speed to give a gentle cooling operation.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
HEAT : 20.0 °C ~ 24.0 °C /
68 °F ~ 75 °F.
COOL: 26.0 °C ~ 28.0 °C /
79 °F ~ 82 °F.
Air ow direction
In COOL/DRY mode:
(CS-FZ25/35/50UKE)
If AUTO is set, the ap swings up/down automatically.
(CS-FZ60UKE)
If
AUTO is set, the ap swings left/right and up/down automatically.
In HEAT mode:
If AUTO is set, the horizontal ap is xed at the predetermined position. The vertical ap
swings left/right after the temperature rises.
Auto restart control
If power is resumed after a power failure, the operation will restart automatically after a
period of time with previous operation mode and air ow direction.
This control is not applicable when TIMER is set.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature
°C (°F)
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 (89.6) 23 (73.4) 43 (109.4) 26 (78.8)
Min. 16 (60.8) 11 (51.8) -10 (14.0) -
HEAT
Max. 30 (86.0) - 24 (75.2) 18 (64.4)
Min. 16 (60.8) - -15 (5.0) -16 (3.2)
DBT: Dry bulb temperature, WBT: Wet bulb temperature