17.4.16. F11 (4-way valve Abnormality)
Malfunction Decision Conditions
When heating operation, when indoor pipe temperature is below 10C
When cooling operation, when indoor pipe temperature is above 45C
Malfunction Caused
Connector in poor contact
Faulty sensor
Faulty outdoor unit PCB
4-way valve defective