C. Control contents
a. Fan Speed manual
1. Fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
2. Fan speed for quiet operation is reduced from setting fan speed.
b. Fan Speed Auto
1. Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger.
12.7. Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/Soft Dry) or higher up
to 3.5°C (for Heating) than remote control setting temperature for 20 minutes to achieve the setting temperature quickly.
12.8. Timer Control
12.8.1. ON Timer Control
ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide
a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine the
indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
12.8.2. OFF Timer Control
OFF timer can be set using remote control, the unit with timer set will stop operate at set time.
12.9. Auto Restart Control
1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four
minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after
power supply resumes.
2. This type of control is not applicable during ON/OFF Timer setting.
12.10. Indication Panel
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, operation mode judgment, or ON timer sampling.
If Timer LED is blinking, there is an abnormality operation occurs.
If e-ion LED is blinking, there is an abnormality of e-ion occurs.
If PATROL LED is blinking, there is a gas sensor error detection.
LED POWER/DEICE TIMER QUIET POWERFUL e-ion +8/10°C HEAT
PATROL
SENSOR
Color Green Blue Orange Orange Orange Blue Green Blue
Light ON
Operation
ON
Deice
Operation
Timer Setting ON Quiet Mode ON Powerful Mode ON e-ion ON +8/10°C HEAT ON PATROL ON
Light OFF Operation OFF Timer Setting OFF Quiet Mode OFF Powerful Mode OFF e-ion OFF +8/10°C HEAT OFF PATROL OFF