38
h. Power failure
• During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation resumes
immediately.
• During combination operation, if power failure occurs, after power resumes combination operation resume immediately.
i. Error Detection Control
• The Patrol error detection control starts once the power is supplied to Patrol sensor. However, the error will display when the
Patrol operation is ON.
• Error detection method:
- If the Patrol sensor feedback is 0V or 5V continuous for 6 hours, Patrol sensor error occurs. However, the error will display
only when the Patrol operation is ON.
• Patrol Sensor Control after error occurs
- During any operation mode combines with Patrol operation
Power supply to Patrol sensor is OFF
Air conditioner normal mode operation continues with Patrol LED and Timer LED blinking and “H58” is indicated.
Timer LED will always blinking and the Patrol LED continues blinking if the Patrol operation is ON and stops blinking if the
patrol operation is OFF.
- During Patrol individual mode
Power supply to Patrol sensor is OFF
Patrol LED and Timer LED blinking and “H58” is indicated.
Timer LED will always blinking and the Patrol LED continues blinking if the Patrol operation is ON and stops blinking if the
Patrol operation is OFF.
• Error cancel condition:
- Power supply reset
12.12. e-ion Operation
A. Purpose
This operation provides clean air by producing negative ions to attract dust captured at the positively charged e-ion filters.
B. Control Condition
a. e-ion operation start condition
• During unit running at any operation mode, if “e-ion” button is pressed, combination operation (operation mode + e-ion
operation) starts.
• During unit is OFF, if “e-ion” button is pressed, e-ion individual operation starts.
b. e-ion operation stop condition
• When “OFF/ON” button is pressed to stop the operation.
• When “e-ion” button is pressed again.
• When “Patrol” button is pressed.
• When OFF Timer activates.
c. e-ion operation pause condition
• When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after indoor fan restarts.
• When indoor intake temperature 40°C. e-ion operation resume after indoor intake temperature < 40°C continuously for 30
minutes.