52
F93 Compressor abnormal
revolution
4 times happen
within 20 minutes
Compressor abnormal
revolution
Power transistor module faulty or
compressor lock
F95 Outdoor cooling high
pressure protection
4 times happen
within 20 minutes
Cooling high pressure
protection
Check refrigeration system
Outdoor air circuit
F96 Power transistor module
overheating protection
4 times happen
within 30 minutes
Power transistor module
overheat
PCB faulty
Outdoor air circuit (fan motor)
F97 Compressor
overheating protection
3 times happen
within 30 minutes
Compressor overheat Insufficient refrigerant
F98 Total running current
protection
3 times happen
within 20 minutes
Total current protection Check refrigeration system
Power source or compressor lock
F99 Outdoor direct current
(DC) peak detection
Continuous
happen for 7 times
Power transistor module
current protection
Power transistor module faulty or
compressor lock
Abnormality /
Protection control
Abnormality
Judgement
Protection
operation
Problem Check location
Diagnosis
display