EasyManua.ls Logo

Panasonic CS-NZ25VKE User Manual

Panasonic CS-NZ25VKE
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© Panasonic Corporation 2019
Order No: PAPAMY1908068CE
DEICE
DEICE
Indoor Unit Outdoor Unit
CS-NZ25VKE
CS-NZ35VKE
CS-NZ50VKE
CS-QZ25VKE
CU-NZ25VKE
CU-NZ35VKE
CU-NZ50VKE
CU-QZ25VKE
Destination
North Europe
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the products dealt with in this service information by anyone else could result in serious injury or death.
IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by in the Schematic
Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced
with manufacturer’s specified
parts to prevent shock, fire or other hazards. Do not modify the original design without permission of
manufacturer.
PRECAUTION OF LOW TEMPERATURE
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
CAUTION
R32 REFRIGERANT – This Air Conditioner contains and operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL.
Refer to National, State, Territory and local legislation, regulations, codes, installation & operation manuals, before the installation,
maintenance and/or service of this product.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-NZ25VKE and is the answer not in the manual?

Panasonic CS-NZ25VKE Specifications

General IconGeneral
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
Power Supply220-240 V, 50 Hz
RefrigerantR32
Outdoor Unit Dimensions (W x H x D)780 x 542 x 289 mm
Weight (Indoor Unit)8 kg
Energy Efficiency Class CoolingA++
Energy Efficiency Class HeatingA+
Coefficient of Performance (COP)4.00
Noise Level (Outdoor)46 dB(A)
TypeSplit System
Noise Level (Indoor)19 dB(A)

Summary

Safety and Precautions

Unit Safety Precautions

Crucial safety warnings for operating and servicing the unit, including hazard symbols and immediate risks.

R32 Refrigerant Safety and Precautions

Specific safety guidelines for using R32 refrigerant, covering flammability, ventilation, and pressure.

Specifications and Features

Performance Specifications

Detailed technical data including cooling, heating, and energy efficiency ratings.

Key Product Features Overview

Overview of advanced features like inverter technology, environment protection, and remote control.

Installation Guide

Installation Location Selection

Guidance on selecting optimal indoor and outdoor unit installation locations.

Indoor Unit Installation Steps

Step-by-step instructions for indoor unit mounting and setup.

Outdoor Unit Installation Procedures

Instructions for installing the outdoor unit, including securing and connecting pipes.

Refrigerant System Leak Testing

Procedure for testing the air tightness of the refrigerant system.

R32 Refrigerant and Piping Services

R32 Refrigerant Characteristics and Safety

Information on R32 refrigerant properties, safety, and environmental impact.

Tools for R32 Piping Installation and Service

Lists essential tools required for R32 refrigerant piping and system services.

Pipe Materials and Processing Procedures

Details copper pipe specifications and steps for cutting and flaring.

Vacuum Pump Air Purging and Leak Testing

Step-by-step guide for air purging and leak testing using a vacuum pump.

Refrigerant Recovery Procedure

Detailed instructions for safely recovering refrigerant from the system.

Refrigerant Re-charging Procedure

Steps for correctly re-charging refrigerant into the system after service.

Brazing Preparation and Techniques

Guidance on preparing for and executing brazing operations on refrigerant circuits.

Operation and Control

Basic Operation Modes Overview

Explanation of core operation modes like cooling, heating, and soft dry.

Automatic Operation Logic Details

Details how the unit automatically selects operating modes based on conditions.

Vertical Airflow Control

How to adjust and control the vertical airflow direction.

Quiet Operation Modes

Instructions for activating and using quiet operation for cooling and dry modes.

Timer and Auto Restart Functions

Explains how to set timers and manage auto restart functionality.

Wireless LAN System Setup and Connection

Introduction to wireless LAN control, setup, and connection procedures.

Managing Wireless LAN Connection

Steps for disconnecting, checking signal, and diagnosing wireless LAN issues.

Protection and Troubleshooting

Unit Protection Mechanisms Overview

Overview of protective controls for various operational conditions.

Cooling Operation Protection

Specific protection controls related to cooling and soft dry modes.

Heating Operation Protection

Specific protection controls for heating mode operations.

Refrigeration Cycle System Troubleshooting

Guide to diagnosing malfunctions within the refrigeration cycle.

Self-Diagnosis Function and Error Codes

How to use the unit's self-diagnosis system and interpret error codes.

Troubleshooting Specific Error Codes

Detailed troubleshooting steps for common error codes (e.g., H14, H15).

Disassembly and Assembly

Indoor Unit Disassembly (NZ25/35/QZ25)

Steps for disassembling indoor units of specific models.

Indoor Unit Disassembly (NZ50)

Step-by-step guide for disassembling the CS-NZ50VKE indoor unit.

Wireless LAN Module Replacement Procedure

Instructions for replacing the wireless LAN module.

Initial App Setup and Network Connection

Steps for setting up the app and connecting to the network.

Outdoor Unit Controller Removal Steps

Procedures for removing the electronic controller from outdoor units.

Technical Data and Parts List

Cool Mode Performance Data

Performance data tables for cooling mode under various conditions.

Heat Mode Performance Data

Performance data tables for heating mode under various conditions.

Cool Mode Outdoor Air Temp. Characteristics

Graphs showing cooling mode characteristics versus outdoor air temperature.

Piping Length Correction Factors

Graphs showing correction factors for cooling and heating based on piping length.

Indoor Unit Parts List and Exploded View

Exploded diagrams and lists of replaceable parts for indoor units.

Outdoor Unit Parts List and Exploded View (CU-NZ25/35/QZ25)

Exploded diagrams and lists of replaceable parts for outdoor units.

CU-NZ50VKE Outdoor Unit Exploded View & Parts List

Exploded diagrams and lists of replaceable parts for the CU-NZ50VKE outdoor unit.

Related product manuals