61
13.3 iAUTO Operation
iAUTO operation can be set using remote control.
This operation is applied to faster cool down time of the room and comfort feel by thermal shift and fan speed
control.
Thermal control
- The internal setting temperature will shift 1°C lower than remote control setting temperature for maximum
4 hours to provide extra cool and better comfort.
Fan speed control
- Fan speed selection is prohibited. Fan speed display at remote control is fixed at AUTO.
- The internal fan speed will set to be SHi initially for maximum 30 minutes to achieve the setting temperature
quickly. Then it will shift between SHi, Hi and Me fan speed depends on intake and setting temperature.
Vane control is follow remote control setting.
13.4 Indoor Fan Speed Control
Indoor fan speed can be set using remote control
13.4.1 Fan Speed Rotation Chart
Speed Fan Speed (rpm)
CS-PC9QKH CS-PC12QKH CS-PC18QKH CS-PC24QKH CS-PC28QKH
SHi 1180 1180 1270 1420 1520
Hi 1150 1150 1240 1390 1490
Me 960 980 1150 1240 1400
HLo 840 850 1130 1210 1330
CLo 770 810 1060 1150 1250
Lo- 730 770 850 970 1050
SLo 710 750 670 750 830
13.4.2 Automatic Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the
table.
o Fan speed rotates in the range of Hi and Me.
o Deodorizing Control will be activated.
(For PC9/12QKH)
Speed Mode SHi Hi Me HLo CLo Lo- SLo Stop
Hi ○ ○
Me ○
Manual
Lo ○
Cooling
Normal
Auto ○ ○ ○ ○
Manual ○ ○
Soft
Dry
Normal
Auto ○ ○
Mode Judgment ○
(For PC18/24/28QKH)
Speed Mode SHi Hi Me HLo CLo Lo- SLo Stop
Hi ○ ○
Me ○
Manual
Lo ○
Cooling
Normal
Auto ○ ○ ○ ○
Manual ○
Soft
Dry
Normal
Auto ○
Mode Judgment ○