69
15.2 Remote Control Button
15.2.1 SET Button
To check current remote control transmission code and store the transmission code to EEPROM:
o Press “Set” button for more than 10 seconds by using pointer
o Press “Timer Set” button until a “beep” sound is heard as confirmation of transmission code change
15.2.2 RESET
To clear and restore the remote control setting to factory default.
o Press once to clear the memory
15.2.3 TIMER ▲
To change indoor unit indicators’ intensity:
o Press continuously for 5 seconds
15.2.4 TIMER ▼
To change remote control display from Degree Celsius (°C) to Degree Fahrenheit (°F)
o Press continuously for 10 seconds
15.2.5 TEMP
To change remote control set temperature range from 16°C ~ 30°C (60°F ~ 86°F) to 20°C ~ 30°C (68°F ~ 86°F).
o Press continuously for 15 seconds.