EasyManua.ls Logo

Panasonic CS-PS18NKV - CS-PS12 NKV CU-PS12 NKV Operation Characteristics

Panasonic CS-PS18NKV
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
91
16.1.2 CS-PS12NKV CU-PS12NKV
• Cooling Characteristic
o Room temperature: 27°C (DBT), 19°C (WBT)
o Operation condition: High fan speed
o Piping length: 7.5m
o Compressor Frequency = Fc
14.900
15.400
15.900
16.400
16.900
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Outlet Air
Tempeature (°C)
Outdoor Air Temperature (°C)
220
2.600
2.700
2.800
2.900
3.000
3.100
3.200
3.300
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Outdoor Air Temperature (°C)
Cooling
Capacity (kW)
3.700
3.900
4.100
4.300
4.500
4.700
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Current
(A)
Outdoor Air Temperature (°C)
1.060
1.070
1.080
1.090
1.100
1.110
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa
)

Table of Contents