16.1.3 CS-PS18NKV CU-PS18NKV
Cooling Characteristic
o Room temperature: 27°C (DBT), 19°C (WBT)
o Operation condition: High fan speed
o Piping length: 5m
o Compressor Frequency = Fc
14.500
14.700
14.900
15.100
15.300
15.500
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Outlet Air
Tempeature (°C)
Outdoor Air Temperature (°C)
220
4.600
4.800
5.000
5.200
5.400
5.600
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Outdoor Air Temperature (°C)
Cooling
Capacity (kW)
6.100
6.600
7.100
7.600
8.100
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Current
(A)
Outdoor Air Temperature (°C)
0.960
0.970
0.980
0.990
1.000
1.010
1.020
1.030
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa
)