Piping Length Characteristic
o Room temperature: 27°C (DBT), 19°C (WBT)
o Operation condition: High fan speed
o Outdoor temperature: 35°C (DBT), 24°C (WBT)
o Compressor Frequency = Fc
2.400
2.500
2.600
2.700
3456789101112131415
Piping Length (m)
Cooling
Capacity (kW)
3.300
3.350
3.400
3.450
3 4 5 6 7 8 9 101112131415
Current
(A)
Piping Length (m)
1.140
1.142
1.144
1.146
1.148
1.150
1.152
1.154
3 4 5 6 7 8 9 10 11 12 13 14 15
Piping Length (m)
Gas Side Piping
Pressure (MPa
)
14.800
14.900
15.000
15.100
15.200
15.300
3456789101112131415
Outlet Air
Temperature (°C)
Piping Length (m)
220